Revert BLtouch to Z-MIN (bltouch deploy during print)

This commit is contained in:
Benoit LORAND 2024-07-02 22:04:21 +02:00
parent d9209b4857
commit c1ce5a1892
6 changed files with 12 additions and 12 deletions

View File

@ -1304,10 +1304,10 @@
* The probe replaces the Z-MIN endstop and is used for Z homing. * The probe replaces the Z-MIN endstop and is used for Z homing.
* (Automatically enables USE_PROBE_FOR_Z_HOMING.) * (Automatically enables USE_PROBE_FOR_Z_HOMING.)
*/ */
//#define Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN #define Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN
// Force the use of the probe for Z-axis homing // Force the use of the probe for Z-axis homing
#define USE_PROBE_FOR_Z_HOMING //#define USE_PROBE_FOR_Z_HOMING
/** /**
* Z_MIN_PROBE_PIN * Z_MIN_PROBE_PIN

View File

@ -912,7 +912,7 @@
// Safety: The probe needs time to recognize the command. // Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed. // Minimum command delay (ms). Enable and increase if needed.
#define BLTOUCH_DELAY 500 //#define BLTOUCH_DELAY 500
/** /**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
@ -920,7 +920,7 @@
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations. // in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE #define BLTOUCH_FORCE_SW_MODE
/** /**
* Settings for BLTouch Smart 3.0 and 3.1 * Settings for BLTouch Smart 3.0 and 3.1

View File

@ -37,7 +37,7 @@
* *
* Advanced settings can be found in Configuration_adv.h * Advanced settings can be found in Configuration_adv.h
*/ */
#define CONFIGURATION_H_VERSION 02010202 #define CONFIGURATION_H_VERSION 02010204
//=========================================================================== //===========================================================================
//============================= Getting Started ============================= //============================= Getting Started =============================
@ -1304,10 +1304,10 @@
* The probe replaces the Z-MIN endstop and is used for Z homing. * The probe replaces the Z-MIN endstop and is used for Z homing.
* (Automatically enables USE_PROBE_FOR_Z_HOMING.) * (Automatically enables USE_PROBE_FOR_Z_HOMING.)
*/ */
//#define Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN #define Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN
// Force the use of the probe for Z-axis homing // Force the use of the probe for Z-axis homing
#define USE_PROBE_FOR_Z_HOMING //#define USE_PROBE_FOR_Z_HOMING
/** /**
* Z_MIN_PROBE_PIN * Z_MIN_PROBE_PIN
@ -1711,8 +1711,8 @@
// Direction of endstops when homing; 1=MAX, -1=MIN // Direction of endstops when homing; 1=MAX, -1=MIN
// :[-1,1] // :[-1,1]
#define X_HOME_DIR -1 #define X_HOME_DIR 1
#define Y_HOME_DIR -1 #define Y_HOME_DIR 1
#define Z_HOME_DIR -1 #define Z_HOME_DIR -1
//#define I_HOME_DIR -1 //#define I_HOME_DIR -1
//#define J_HOME_DIR -1 //#define J_HOME_DIR -1

View File

@ -32,7 +32,7 @@
* *
* Basic settings can be found in Configuration.h * Basic settings can be found in Configuration.h
*/ */
#define CONFIGURATION_ADV_H_VERSION 02010202 #define CONFIGURATION_ADV_H_VERSION 02010204
// @section develop // @section develop
@ -912,7 +912,7 @@
// Safety: The probe needs time to recognize the command. // Safety: The probe needs time to recognize the command.
// Minimum command delay (ms). Enable and increase if needed. // Minimum command delay (ms). Enable and increase if needed.
#define BLTOUCH_DELAY 500 //#define BLTOUCH_DELAY 500
/** /**
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones: * Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
@ -920,7 +920,7 @@
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful // Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
// in special cases, like noisy or filtered input configurations. // in special cases, like noisy or filtered input configurations.
//#define BLTOUCH_FORCE_SW_MODE #define BLTOUCH_FORCE_SW_MODE
/** /**
* Settings for BLTouch Smart 3.0 and 3.1 * Settings for BLTouch Smart 3.0 and 3.1